Retro video games delivered to your door every month!
Click above to get retro games delivered to your door ever month!
X-Hacker.org- CA-Clipper 5.2 . The Guide To CA-Clippe - <b>readkill()</b> http://www.X-Hacker.org [<<Previous Entry] [^^Up^^] [Next Entry>>] [Menu] [About The Guide]
 READKILL()
 Return, and optionally set, whether the current READ should be exited
------------------------------------------------------------------------------
 Syntax

     READKILL([<lKillRead>]) --> lCurrentSetting

 Arguments

     <lKillRead> sets the READKILL() flag.  A value of true (.T.)
     indicates that the current read should be terminated, and a value of
     false (.F.) indicates that it should not.

 Returns

     READKILL() returns the current setting as a logical value.

 Description

     READKILL() is a Get system function that lets you control whether or not
     to terminate the current READ.

     Unless directly manipulated, READKILL() returns true (.T.) after you
     issue a CLEAR GETS (see the CLEAR GETS entry in the Reference guide) for
     the current READ and otherwise returns false (.F.).

     By accessing the function directly, however, you can control the
     READKILL() flag with its function argument and use it to create new READ
     Layers.

 Files:  Library is CLIPPER.LIB, source file is Getsys.prg.

See Also: CLEAR GETS READFORMAT() READUPDATED()

Online resources provided by: http://www.X-Hacker.org --- NG 2 HTML conversion by Dave Pearson